This compact all-inclusive analyzer is ready to operate in harsh environments. The Galvalibs 2.0 has been designed with the operator in mind. It’s lightweight and easy to connect and disconnect for no-hassle manipulation.
Sturdy hollow ceramic cylinder for inserting probing gas bubbles deep into the molten metal. One lance is used for multiple baths and many years.
Easily insert and extract the probe from the molten bath. The device automatically positions the probe near the surface, before insertion to allow moisture removal and thermal balancing of the lance. The motorized positioning device makes operation easy.
Easily insert and extract the probe from the molten bath. Low-cost alternative to the motorized positioning device.
Robust industrial-grade control unit for easy access to data and status of the analyzer.
Keep your data unbiased and your lance clean with Tecnar’s specifically designed gas supply system. The flexible stainless steel line prevents impurities from reaching the measurement environment.
Get your data anywhere at any time with a Galvalibs 2.0 interface with your plant network.
The Galvalibs 2,0 Calibration Unit (GCU) gives operators the ultimate autonomy to perform routine calibrations without a laboratory.
Element range
Effective aluminum: 0.020 wt% to 60 wt%
Dissolved iron: 0.008 wt% to 3.0 wt%
Soluble magnesium: 0.001 wt% to 6.0 wt%
Soluble silicon: 0.001 wt% to 15.0 wt%
Chemistry accuracy
Residual standard deviation (RSD): 0.5%
Bath-level accuracy
Residual standard deviation (RSD): 0.4 mm
Residual standard deviation (RSD): 0.16 in.
Gi-Ga element range
Al: 0.100 wt% to 0.700 wt%
Fe: 0.008 wt% to 0.032 wt%
Zn-Al-Mg element range
Al: 1.0 wt% to 12.0 wt%
Fe: 0.010 wt% to 0.050 wt%
Mg: 1.0 wt% to 6.0 wt%
Al-Si element range
Si: 8.0 wt% to 12.0 wt%
Fe: 1.0 wt% to 3.0 wt%
Chemistry accuracy
Residual standard deviation (RSD): 2%
Electrical supply
200 - 240 VAC @ 50 or 60 Hz, -5%/+10%, 4 to 7 Amp
Compressed air supply
Instrument compressed air (ANSI/ISA-7.0.01), 550 kPa, 42.5 to 68 m³/hr
Instrument compressed air (ANSI/ISA-7.0.01), 80 psi, 25 to 40 cfm
Gas supply
Argon quality: minimum gas purity 4.8 (99.998%)
Average consumption: 0.75 LPM
Probe (without lance)
499 mm x 338 mm x 141 mm
21 kg
20 in. x 13 in. x 5.6 in.
45 lbs.
Lance
111 mm x 83 mm x 821 mm
4 kg
4.4 in. x 3.3 in. x 32.3 in.
9 lbs.
Motorized positioning device
1795 mm x 444 mm x 852 mm
110 kg
Standard extension - 450 mm
Standard travel range - 900 mm
70.7 in. x 17.5 in. x 33.5 in.
243 lbs.
Standard extension - 17.7 in.
Standard travel range - 35.4 in.
Manual positioning device
1769 mm x 512 mm x 852 mm
100 kg
Standard extension - 450 mm
Standard travel range - 900 mm
69.6 in. x 20.2 in. x 33.5 in.
220 lbs.
Standard extension - 17.7 in.
Standard travel range - 35.4 in.
Control unit
884 mm x 818 mm x 365 mm
100 kg
NEMA 3/12 Enclosure
34.8 in. x 32.2 in. x 14.4 in.
220 lbs.
NEMA 3/12 Enclosure
Probe to control unit bundle
20 m long
3 m long zinc splash-resistant cover at the probe
Standard travel range - 900 mm
65 ft. long
10 ft. long zinc splash-resistant cover at the Probe standard travel range - 35.4 in.
Gas management
Ultra-high-purity grade components
Inlet pressure up to 275 bar
100% stainless steel flexible line
30 m long
Pressure tested for leak-free operation
Ultra-high-purity grade components
Inlet pressure up to 3000 psi
100% stainless steel flexible line
100 ft. long
Pressure tested for leak-free operation
GCU
407 mm x 234 mm x 238 mm
7.1 kg
16 in. x 9.2 in. x 9. in.
15.5 lbs.